Issue

  • When upgrading to the Liferay DXP 7.4, navigate to the Control Panel > System > Gogo Shell and execute the ds:unsatisfied command, then getting the Unsatisfied Reference - Unresolved Declarative Service and below error:
    Bundle {id: 5125, name: com.liferay.portal.security.audit.event.generators, version: 5.0.13}
    	Declarative Service {id: 11494, name: com.liferay.portal.security.audit.event.generators.internal.events.LoginPostAction, unsatisfied references: 
    		{name: _filter, target: (component.name=com.liferay.portal.security.audit.wiring.internal.servlet.filter.AuditFilter)}
    	}

Environment

  • Liferay DXP 7.4

Resolution

  • The mentioned unsatisfied reference message appears when the Audit module is disabled in the environment.
  • To enable the Audit, navigate to the Control Panel > System Settings > Audit. Then check the 'Enabled' checkbox and click on 'Save'.