Unsatisfied Reference - Unresolved Declarative Service
Written By
Anushka Tiwari
How To articles are not official guidelines or officially supported documentation. They are community-contributed content and may not always reflect the latest updates to Liferay DXP. We welcome your feedback to improve How To articles!
While we make every effort to ensure this Knowledge Base is accurate, it may not always reflect the most recent updates or official guidelines.We appreciate your understanding and encourage you to reach out with any feedback or concerns.
Legacy Article
You are viewing an article from our legacy "FastTrack"
publication program, made available for informational purposes. Articles
in this program were published without a requirement for independent
editing or verification and are provided"as is" without
guarantee.
Before using any information from this article, independently verify its
suitability for your situation and project.
Issue
- When upgrading to the Liferay DXP 7.4, navigate to the Control Panel > System > Gogo Shell and execute the ds:unsatisfied command, then getting the Unsatisfied Reference - Unresolved Declarative Service and below error:
Bundle {id: 5125, name: com.liferay.portal.security.audit.event.generators, version: 5.0.13}
Declarative Service {id: 11494, name: com.liferay.portal.security.audit.event.generators.internal.events.LoginPostAction, unsatisfied references:
{name: _filter, target: (component.name=com.liferay.portal.security.audit.wiring.internal.servlet.filter.AuditFilter)}
}
Resolution
- The mentioned unsatisfied reference message appears when the Audit module is disabled in the environment.
- To enable the Audit, navigate to the Control Panel > System Settings > Audit. Then check the 'Enabled' checkbox and click on 'Save'.
Did this article resolve your issue ?