Issue
- After creating a structure with repeatable fields, when trying to delete a field by clicking the "-" button, the field is not deleted.
Steps to reproduce
- Navigate to Content & Data > Web Content > Structures.
- Create a new structure as follows:
- Field 1
- Type: Text
- Localizable: Yes
- Repeatable: Yes
- Field 2 (this field must be inside the previous field)
- Type: HTML
- Localizable: No
- Repeatable: No
- Field 1
- Save.
- Create a new Web Content based on this structure.
- Click the "+" button to add new fields.
- Try deleting a field by clicking the "-" button
Environment
- Liferay DXP 7.2.X
- Liferay DXP 7.3.X
Resolution
- Please request a Hotfix with LPS-167057 to resolve the issue.
Additional Information
- In Liferay 7.2.X, Patching Tool 2.0.16 or higher is required to install this Hotfix.
- Updating the Patching Tool
- Installing Fix Packs and Hotfixes on Liferay DXP